Commercial Freezer Condensation Restoration

Restoring the thermal envelope of a commercial freezer and refrigerated ceiling with continuous spray-applied polyurethane foam, penetration detailing and weather protection at roof piping assemblies.

Request a Quote (RFQ)
Services

Insulation & Spray Foam, Protective Coatings, Containment

Environment

Cold Storage, Food & Beverage

Location

Carpentersville, Illinois

Year

2026

Green Peak completed a multi-area cold-storage insulation project at an operating food processing facility in Carpentersville, Illinois. The existing ceiling and pipe transitions showed frost, ice accumulation and deteriorated insulation. The objective was to address the conditions that contribute to condensation, rather than simply remove visible moisture.

When warmer, moisture-laden air reaches a cold surface below its dew point, condensation can form. Discontinuous insulation at insulated metal panel (IMP) seams, walls and mechanical penetrations can also allow heat transfer and localized freezing. A continuous thermal, air and vapor control layer was the basis of the proposed approach.

The original freezer scope specified approximately 5.5 inches nominal (5 inches minimum) of 2 lb closed-cell spray polyurethane foam applied above the freezer ceiling and around the curb-wall transition, overlapping approximately 2 feet onto the adjacent refrigerated ceiling. The proposed freezer area was approximately 10,270 square feet. The adjacent refrigerated ceiling scope specified approximately 4 inches of 2 lb closed-cell spray foam across approximately 30,764 square feet, with service penetrations detailed as applicable. These are original proposal quantities and thicknesses, rather than an as-built quantity survey.

The specified pipe-penetration work included approximately 4 to 6 inches of closed-cell foam around designated freezer ammonia piping and approximately 4 inches around accessible refrigerated-area penetrations. The roof assembly scope included restoration of deteriorated insulation as required and a UV-resistant silicone protective finish, specified at approximately 24 mils. Electrical penetration locations were identified for future service, and access, containment and work-area protection were part of the project planning.

The supplied after photographs show continuous spray foam coverage above the ceiling, foam detailing around connections, marked service locations and white-coated above-roof pipe assemblies. The project video documents the work and the approach to the condensation problem. The final performance of any cold-storage insulation system depends on temperature, humidity, substrate condition, system continuity and facility-specific operating conditions.

Project video

Before and after

Representative views above the cold-storage ceiling. The photos document the existing assembly and the completed spray foam coverage, rather than a precisely matched camera angle.

Existing insulated metal panel ceiling and unsealed transitions.Before
Existing insulated metal panel ceiling and unsealed transitions.
Continuous spray foam coverage with detailing around service penetrations.After
Continuous spray foam coverage with detailing around service penetrations.

What we found on site

Damaged existing insulation

Damaged existing insulation

Removed insulation showed visible deterioration and discoloration.

Discontinuous pipe insulation

Discontinuous pipe insulation

Existing insulation at pipe transitions had visible gaps and damaged areas.

Frost and ice accumulation

Frost and ice accumulation

Ice was visible near the ceiling and wall transition inside the cold space.

Insulation system details

Original proposal illustrations show the intended insulation continuity at the freezer wall, roof deck, piping and refrigerated-ceiling penetrations. These are design details, not as-built measurements.

Annotated spray foam system diagram showing freezer wall transition and roof deck piping detailsView full-size annotated rendering
Annotated refrigerated ceiling insulation and sprinkler penetration cross sectionView full-size annotated rendering

Project photography

39 actual field photos. Select a photograph to view it in full.

Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 1Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 2Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 3Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 4Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 5Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 6Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 7Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 8Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 9Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 10Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 11Commercial Freezer Condensation Restoration: Completed insulation work above the cold-storage ceiling 12