Project

Mixed-Use Roof Insulation & Silicone Restoration

Three inches of 3 lb closed-cell spray foam and a silicone roofing finish for an existing EPDM roof above a coffee shop and apartments experiencing heat loss, condensation and leaks.

Request a Quote (RFQ)
Services

Roof Restoration, Protective Coatings, Insulation & Spray Foam

Environment

Mixed-use commercial and residential building

Location

Little Chute, Wisconsin

Year

2019

Green Peak restored the roof of a mixed-use building with a coffee shop and apartments in Little Chute, Wisconsin. The existing roof lacked sufficient insulation to retain heat in the apartments, resulting in condensation concerns. The building was also experiencing roof leaks.

Where the existing EPDM membrane was firmly adhered and suitable for the specified restoration, it was retained as the substrate. Loose and inadequately bonded roofing material was removed, and the new insulation was sprayed directly onto the exposed substrate in those affected areas.

The roof received 3 inches of 3 lb density closed-cell spray polyurethane foam, installed in two 1.5-inch passes. This created a continuous insulation layer across the treated roof surfaces, addressing the project's thermal needs. A silicone protective coating was applied over the foam to form the waterproofing layer.

Retaining serviceable existing roofing where appropriate reduced unnecessary removal. The result was a continuous insulated and silicone-coated roof assembly designed to address the building's heat retention, condensation and leak concerns. Current photographs show the completed roof and selected transitions around rooftop equipment.

Project photography

7 actual field photos. Select a photograph to view it in full.

Mixed-Use Roof Insulation & Silicone Restoration: project photograph 1Mixed-Use Roof Insulation & Silicone Restoration: project photograph 2Mixed-Use Roof Insulation & Silicone Restoration: project photograph 3Mixed-Use Roof Insulation & Silicone Restoration: project photograph 4Mixed-Use Roof Insulation & Silicone Restoration: project photograph 5Mixed-Use Roof Insulation & Silicone Restoration: project photograph 6Mixed-Use Roof Insulation & Silicone Restoration: project photograph 7

Project starter

Start your project with a conversation.

Tell us about your roof restoration needs, and we will develop a scope for your facility.